Radiator & Htr
& condensor Calorimeter System
- Radiator Performance test
- Heat core performance test
- PTC Heater performance test
- Condensor performance test
- Cooling Fan Performance Test
Feature
- Vehicle equipment test
- Construction equipment test
- High precision air flow measurement of flow nozzle type (ASHRAE Standard)
- Automatic nozzle selection by air volume band
- Automated Test Preparation Logic
- Apply high precision static pressure & differential pressure sensor
- Apply high precision RTD temperature sensor
- Apply high precision coriolis type mass flow meter
- Real time density measurement
- Refrigerant circulation system for condenser test
- Compressor speed control for condenser test
- Data collection and computation through LabVIEW® automation software packages
- Be possible Variable data collection to DAQ system
- Performance test of PTC heaters, cooling fans and heat cores
Specifications
MODEL |
SEOUL-RHCCS-8848-1Series |
Test Sample |
Radiator |
Condensor |
Heater Core |
Capacity |
100,000kcal/h (116kW) |
30,000kcal/h(34kw) |
20,000kcal/h(17kw) |
Temperature Control Range |
± 0.2℃ |
Accuracy |
± 0.2℃ |
Humidity Control Range |
30 ~ 90% RH |
Accuracy |
± 2% |
Air Flow Rate |
500 ~ 14000CMH |
Coolant Flow Rate Range |
Upto ~ 600 ℓ/m ( 36,000 ℓ/h ) |
Coolant Temperature Range (at EG 50%) |
35~120℃ |
Accuracy |
± 0.2℃ |
Refrigerant Flow Rate |
Upto ~ 600kg/h |
Refrigeration |
R134a , R123yf (Option R744) |
Construction / Control
Construction |
Control Room + Test Room + Machine Room |
Control |
Manual / Full Automatic |
Control Interface |
LabVIEW SoftWare with PC interface |