Durability Test
Inter Cooler(CAC) T-Cycle
- Thermal cycle test inter cooler(CAC) of the wide selection
- The various safety device is embodied
- Controls all functions from software
- Guarantee the test which is stabilized
- Supports a calibration mode (S/W)
- Also the order production for the customer is possible
Feature
- Test room - Walk in type
- Charged air pressurized system - Air compressor & Pipe line
- Charged air temperature control system - Heater & Cooler
- Meeasurement - Points by temperature, flow rate
- DAS - Field Point & Labview S/W
Specifications
MODEL | SEOUL-TCT-CAC-8848-2 series |
---|---|
System | Air compressor, Heat exchanger, Pipe line system |
Compressed Air | Max. 740 kPa |
Safety device | Heater E.O.C.R, SCR Over Current, Pressure H.P S/W High Temperature : High Limit cut off |
Pressure Range | 0 ~ 500 kPa (±2.0%) |
Charge Air Temperature | Up to 280℃ (± 3℃) |
Charge Air Flow Range | 0 ~ 1000 kg/hr |
Charge Air Flow Control | Mass Flow Control ( 500 kg/h×2 Loop) |
Ambient Temperature | 25 ~ 60℃ |
Total Test Cycle | 1,000,000 cycles |
Refrigerator | Capacity : 10HP, Condenser Type : Water cooled |
Test Room | 5.0m(W) * 2.8m(H) * 2.8m(L) Insulation : Poly Urethane 100t |
Frame
Material | Poly Urethane + Steel plate + Board |
---|---|
Sizing | Layout Area : 8.8m(W) × 3.5m(H) × 5.0m(L) |