제품소개

Durability Test

제품사진

Inter Cooler(CAC) T-Cycle

  • Thermal cycle test inter cooler(CAC) of the wide selection
  • The various safety device is embodied
  • Controls all functions from software
  • Guarantee the test which is stabilized
  • Supports a calibration mode (S/W)
  • Also the order production for the customer is possible
Feature
  • Test room - Walk in type
  • Charged air pressurized system - Air compressor & Pipe line
  • Charged air temperature control system - Heater & Cooler
  • Meeasurement - Points by temperature, flow rate
  • DAS - Field Point & Labview S/W
Specifications
MODEL SEOUL-TCT-CAC-8848-2 series
System Air compressor, Heat exchanger, Pipe line system
Compressed Air Max. 740 kPa
Safety device Heater E.O.C.R, SCR Over Current, Pressure H.P S/W
High Temperature : High Limit cut off
Pressure Range 0 ~ 500 kPa (±2.0%)
Charge Air Temperature Up to 280℃ (± 3℃)
Charge Air Flow Range 0 ~ 1000 kg/hr
Charge Air Flow Control Mass Flow Control ( 500 kg/h×2 Loop)
Ambient Temperature 25 ~ 60℃
Total Test Cycle 1,000,000 cycles
Refrigerator Capacity : 10HP, Condenser Type : Water cooled
Test Room 5.0m(W) * 2.8m(H) * 2.8m(L)
Insulation : Poly Urethane 100t
Frame
Material Poly Urethane + Steel plate + Board
Sizing Layout Area : 8.8m(W) × 3.5m(H) × 5.0m(L)
Operating Mode
Operating Type Manual / Full Automatic
Operating Interface LabVIEW SoftWare with PC Interface