Durability Test
EGR Cooler, ATF Warmer
- Test the durability and an internal pressure of the EGR cooler / ATF Warmer of Various types
- The various safety device is embodied
- Controls all functions from software
- Guarantees the test which is stabilized
- Oil level alarm system
- Also the order production for the customer is possible
Feature
- Test sample mounting chamber
- Recever Tank (Bubble prevention) - Safety glass & Safe watch
- Oil Loop System - Drain valve & Return valve
- Safety Device - Emergency stop switch, Shot breaker
- Control Panel - Controller, Counter, Timer & Indicator
- Instrumentation - Points by temperature, flow rate
- Control switch & Alarm detection - PLC Control
Specifications
MODEL | SEOUL-PCT-EGRC-8848-3 Series |
---|---|
System | Cylinder Actuator, Heat exchanger, Pipe line system |
Compressed Air | 600 kPa |
Safety Device | Heater E.O.C.R, SCR Over Current, Pressure H.P S/W High temperature : High Limit cut off |
Pressure Range | 0 ~ 100 MPa |
Temperature | Hot temperature 15~ 130℃ ±3℃ |
Pressure Rising Time | 100 kPa within 1min |
Test Cycle | 1,000,000 Cycles |
Pressure Control | Manual & Auto feedback PID |
Oil Tank | 40 Liter |
Test Room | 1400(W) * 1500(H) * 1200(D) Leakage sensor, Exhaust fan, CCD camera |
Data Acquisition | Custom Spec. |
Test Sample | Max. 6 simultaneous tests |
Control
Control | Manual / Auto |
---|---|
Control Interface | Directreading / LabVIEW SoftWare With PC Interface |