제품소개

Exhaust gas Thermal Simulation System

제품사진

EGR Cooler Performance
& Thermal Cycle Tester
(Chamber Type)

  • Respond to various temperature and flow ranges
  • Various automatic pattern test
  • EGR cooler performance test
  • EGR cooler thermal shock (cycle) test (Thermal durability test)
  • EGR cooler Coolant boiling test
  • EGR cooler connection pipe & tube parts durability test
  • The following standards apply. ISO 21441
Feature
  • Test sample mounting chamber (Option)
  • Various gas-fuel - CNG, LPG, LNG, etc.
  • Gas-fueled & combustion air flow control - Mass flow control type
  • Operating status display panel
  • Alarm and safety equipment system
  • Combustion type - Direct combustion
  • Control Panel - Alarm lamp, Controller, Control S/W
  • Meeasurement - Points by temperature, flow rate and pressure measurement
  • DAS - NI DAQ module & Labview S/W
Patent

KR No. 10-0603502 / 10-1075534 / 10-1296395 / 10-1296396

Specifications
MODEL SEOUL-EGTC-1200D-400K Series SEOUL-EGTC-1200D-1000K Series
System Gas Burner, Test chamber, Combustion system, Coolant system, Control system
Gas Burner Capacity Max. 200,000 kcal/h Max. 380,000 kcal/h
Safety device Gas Detector, Flame Detector, Gas & Air Low Pressure S/W
High Temperature Limit cut off
Fuel Gas CNG (supply pressure) : 200 ~ 500 kPa
LNG, LPG (Vaporization supply pressure) : 200 ~ 500 kPa
Flow Control Type Mass Flow Control
Exhaust Gas Flow Range 10 kg/hr ~ 400 kg/hr 50 kg/hr ~ 1000 kg/hr
Exhaust Gas Temp. Range 150℃ ~ 1150℃ (Max. 1200℃)
Coolant Fluid Water, Ethylene glycol
Coolant Flow Rate Range 5 ~ 150 liter/min
Coolant Temperature Range (at EG 50%) 30 ~ 115℃ (Max. 120℃)
Coolant Flow Control Pump Inverter Control
Frame
Material 'Steel & Stainless & Aluminum
Size Combbustion Chamber & Burner : D320 × 1750
Test Chamber : 2800(W) × 1200(D) × 2200(H)
Operating Mode
Operating Type 'Manual / Full Automatic
Operating Interface LabVIEW SoftWare With PC Interface