Exhaust gas Thermal Simulation System
CVE component
Performance Tester
(DPF, DOC, SCR)
- Emission line component durability test
- Emission line component performance test
- Emission line component thermal shock (cycle) test
- CVE component test (DPF, DOC, TR, SCR, etc. including)
- LVE exhaust system verification test
- NOx gas & Urea reaction effect verification test
- Various automatic pattern test
Feature
- Water Spray Test Chamber
- Various gas-fueled response - CNG, LPG, LNG, etc.
- Gas-fueled & combustion air flow control - Mass flow control type
- Facility working state display panel
- Alarm and safety equipment system
- Combustion type - Direct combustion
- Urea & NO, NO2 Gas Supply System
- Emission gas collection probe X-Y traverse system
- Instrumentation - Points by temperature, flow rate and pressure measurement
- DAS - NI DAQ module & Labview S/W
Patent
KR No. 10-1296395 / 10-1296396
Specifications
MODEL | SEOUL-EGT-NOx-1200D-1000K-Series |
---|---|
System | Gas Burner, Combustion Control Unit, Nox & Urea Supply Unit, X-Y Traverse Unit, Water Spray Test Chamber |
Gas Burner Capacity | Max. 350,000 kcal/h |
Safety device | Gas Detector, Flame Detector, Gas & Air Low Pressure S/W High Temperature Limit cut off |
Exhaust Gas Flow Range | 30 kg/hr ~ 1000 kg/hr |
Exhaust Gas Temp. Range | 150℃ ~ 1150℃ (Max. 1200℃) |
Fuel Gas | CNG (supply pressure) : 200 ~ 500 kPa LNG, LPG (Vaporization supply pressure) : 200 ~ 500 kPa |
Flow Control Type | Mass Flow Control |
Water Spray Nozzle & Water Flow Rate | Spray Nozzle 16 Q'ty Cone type Water Flow Rate : Max 80 liter/min |
Urea Flow Rate | 10 ~ 500 mg/sec |
NO, NO2 gas Flow Rate | NO (99.9%) : 80 ~ 11,000 ml/min NO2 (99.9%) : 6 ~2400 ml/min |
NO, NO2 gas Flow Control Type | Mass Flow Control |