Air Conditioning System Condenser Calorimeter System
- Condensor performance test
- Heater core performance test
- System matching test
- Heat exchanger external prossure drop test
- Heat exchanger's thermal distribution
- Heat exchanger module’s Intake/Outlet temperature test
Feature
- High precision air flow measurement of flow nozzle type (ASHRAE Standard)
- Measuring comp torque by torque detector
- Blower RPM measuring
- Electric heating & Steam injection system
- Each room environment control
- Calculate efficiency , compressor power
Enthalpy , Entropy , Sub Cool, Superheat
specific volume , Heat balance
- Apply high precision pressure sensor
- Apply high precision temperature sensor
- Programmable DC power supply
- Blower RPM measuring
- Data collection and computation through LabVIEW® automation software packages
- Be possible Variable data collection to DAQ system
Specifications
MODEL |
SEOUL-ACSCC-8848-1 Series |
Capacity |
30,000kcal/h(34kw) |
Temperature Control Range |
10 ~ 60℃ |
Accuracy |
± 0.2℃ |
Humidity Control Range |
30 ~ 90% RH |
Accuracy |
± 5% |
Air Flow Rate |
500 ~ 14000 CMH |
Test Core Size |
Max. 900(W) X 700(H) X 500(D) |
Stability |
±0.2℃ S.P at Typical test point, ±0.5℃ S.P at worst case |
Heating & Cooling rate |
1.5℃/min , 0.7℃/min without product load |
Core Tunnel Specification |
Air flow Stability : ±1% S.P Inc Nozzle D.P sensor |
Sensor |
±0.25% S.P Inc High Accuracy Nozzle D.P sensor |
Air Flow Control |
Blower RPM, Bypass Damper, and PID |
Construction / Control
Material |
Rolled Acrylic & Stainless & Aluminum |
Outside Dimension |
Room 2.5(W) X 6(D) X 2.7(H) |
Control |
Possible Both Automatic and Manual |
Control Interface |
LabVIEW SoftWare with PC interface |