Internal Corrosion Tester
- Radiator,Heater Core,Water Cooled CAC, Cooling Module
- Corrosion Circulation Loop system (6Loop)
- Program logic control - switch contorl -Timer/count
- Guarantees the test which is stabilized
- Safety logic
- Also the order production for the customer is possible
- Resistant to corrosiveness(Electrolytic Polishing) SUS316L
Feature
- Test room - Chamber
- Chamber & Piping Material - Sus316L ,Resistant to corrosiveness
- Corrosion heating system - Heater & Receiver tank
- Pressure Control system - Discharg & Back Pressure
- Indicator - Controller, Counter, Timer & Indicator
- Instrumentation - Sensor & Converter
- PLC - Program Logic Controller & Switch Control
- Circulation Cycle test - Flow rate change
Specifications
MODEL |
SEOUL-ICT-8848-1 Series |
System |
Cooling module & Radiator,Heater core,Water Cooled |
Soure Air Pressure |
500 ~ 600 kPa (clean air filter) |
Safety Device |
Heater E.O.C.R, SCR over current, Pressure H.P S/W High temperature : High Limit cut off |
Interal Line Pressure |
5 ~ 500 kPa |
Temperature |
50 ~ 120℃ ±0.2℃ |
Flow Rate |
Electromagnetic Flowmeter Type Max. 50 LPM |
Chamber Temperature |
20~30℃ |
Test Cycle |
6 Loop / Temp & Flow & Pressure |
Refrigerator |
Water cold condending system |
Pressure Transducer |
0 ~ 500 kPa ±0.75% FS |
Temperature Sensor |
-50 ~ 150℃, RTD PT100 |
Construction
Material |
Resistant to corrosiveness(Electrolytic Polishing) SUS316L |
Sizing |
Exterior 2200(W) * 2100(H) * 2800(D) Test Room 1600(W) *1300(H) * 850(D) |
Control
Control |
Manual / Full Automatic |
Control Interface |
PLC & Switch Control (Controller) |